一, The equipment profile
YC-1500 / YC-1500L, YC-1600 / YC-1600L series of tunnel automatic aging machine - is our company for lead aluminum electrolytic capacitors developed by a aging test equipment; the equipment used by my company's latest research and development of the fourth On behalf of the mechanical feed, to ensure that the equipment feeding rate and equipment stability, simple and easy to understand the Chinese user interface, convenient and efficient to improve production efficiency and reduce unnecessary waste and labor costs.
1, the aging temperature: in the room temperature to 105 ℃ within the free set;
2, YC-1500 / YC-1600 device weight about 2500KG, YC-1500L / YC-1600L device weight about 3000KG;
3, equipment size (area): YC-1500 / YC-1600: 5200mm (L) × 3500mm (W) × 2200mm (H);
YC-1500L / YC-1600L: 6600 mm (L) x 3500 mm (W) x 2200 mm (H);
4, the total power of about 18KW equipment, the average production of the average operating power: 226 Bracket equipment ≤ 11KW, 300 Bracket equipment ≤ 14KW;
二, The scope of adaptation:
Equipment model |
Product shell number |
Aluminum height |
Production voltage |
The number of racks |
Number of clamps |
Number of products carried |
Thickness of partition |
Aging power supply |
YC-1500 |
Ф13-18 |
20-45mm or 25-50mm or 30-55mm |
250-600V/2A |
226 only |
30 only |
6780 only |
4.8 mm |
20 segment |
YC-1500L |
300 only |
9000 only |
||||||
YC-1600 |
Ф16-22 |
20-45mm or 25-50mm or 30-55mm |
250-600V/3A |
226 only |
30 only |
6780 only |
6.4 mm |
20 segment |
YC-1600L |
300 only |
9000 only |
Note: The device has data acquisition function for customers matching.
Instrumentation indicators
1, the capacity test range: 0.01μF ~ 10000μF / test accuracy: ± 1%
2, the loss angle: 0.001-0.999, the test accuracy: ± 1.0% ± 1 word;
3, capacity test frequency: 120Hz, 1KHz (2 kinds) can be set alone;
4, leakage current test range: 0.005μA-9999μA, test accuracy: ± 1% ± 0.2μA, two leakage test;
5, ESR test range: 0.01mΩ-999kΩ, test accuracy of ± 1.0%, ESR test frequency: 1K / 10K / 20K / 100K Hz can be set separately (this feature optional);
三, The working principle:
1, the product guide needle shaping and do polarity detection, open circuit, short circuit and reverse polarity detection; exclude open circuit, bending feet, short circuit and reverse pole products;
2, the product into the oven for high temperature by the linear power supply charging aging;
3, the product after the discharge cooling, the aging product is not detected, will exclude the aging products;
4, the product after discharge capacity and loss of the angle test;
5, the product after the discharge by the "ESR" test; (this feature matching);
6, the product recharging about 40 seconds after the leakage current test;
7, the test results are: good products, poor capacity, high loss, large leakage, high impedance and re-seized goods;
四, The equipment performance:
Models |
YC-1500/YC-1600 |
YC-1500L/YC-1600L |
||||||||||||
Stalls out of the material |
150 |
180 |
210 |
240 |
270 |
300 |
360 |
180 |
210 |
240 |
270 |
300 |
330 |
360 |
Go in and out every minute |
45 |
35 |
32 |
28 |
25 |
22 |
18 |
50 |
42 |
37 |
33 |
30 |
27 |
25 |
1, the number of incoming and outgoing materials for the "test run" the actual number of minutes per minute, the error within ± 2;
2, the user can according to their own characteristics of the product stalls to select the product to ensure that the aging effect.
3, leakage test power and charging power and not aging Charging power and test power are used to establish an independent way to effectively ensure the accuracy of product testing.
五, the use of environmental conditions:
1, using three-phase five-wire AC380V ± 5% 50Hz / 10KVA power supply;
2, the use of ambient temperature: room temperature;
3, the characteristics of the guarantee range: 23 ± 5 ℃, 45 ~ 75% RH;
4, need to use pressure ≥ 0.35MPa compressed air.